F31HC-F35HC-UL

5 PRODUCT WARRANTY STATEMENT The manufacturer warrants the product(s) supplied to be free from defects in materials and workmanship when selected, applied, instal- led, operated, serviced and maintained under normal use and in accordance with all established industry standards and generally accep- ted field practices for a period of (12) months from the date of installation or (18) months from original manufacture date - whichever ocurrs first. The manufacturer shall, at their sole discretion, repair or replace any product which, based upon their own or their agents inspection, has failed due to a defect in design, workmanship or materials. This warranty does not cover any product which has failed due to ordinary wear and tear, damage during original shipment or installation, improper application or design, operation, service or maintenance, or which has been subjected to products of corrosion - either internal to the sealed refrigeration system or external in the immediate envi- ronment of the equipment installation. In the case of any products which must be returned to the sellers manufacturing facility for inspection and / or repair, return freight will be pre-paid via regular ground service, the product inspected and either replaced or repaired and re-shipped via ground service. Such ac- tions shall be construed as satisfactory to satsify any and all warranty obligations by the original manufacturer. Prior to the return of any product, written approval must be obtained from the manufacturer along with an RMA number (Return Material Authorization). Any product returned without prior approval and no RMA number will be refused! The manufacturer shall have no liability whatsover for any or all of the following which might be incurred as a result of product failure. These include (but may not be limited to); - Field Labor And Materials - Product Loss - Property Damage - Injury To Personnel - Temporary Equipment Rental / Storage Charges - Installation Charges—including but not limited to labor, materials (including refrigerant), rigging and handling equipment, disposal charges, environmental fees, etc.. For any component / parts or coatings supplied with the unit but not directly produced by the unit manufacturer only the warranty provi- ded to the manufacturer will be extended to the customer. No other warranty shall be assumed or implied by any third party supplier. Any repairs or modifications made to equipment or integral components by a third party or end user without previous authorization from the original equipment manufacturer will be the sole responsibility of that party. Product warranty coverage shall remain intact for the (1) year warranty period based upon the original unit ship date regardless of any changes in ownership of the equipment or the servicing agent. Removal or otherwise defacing of the original unit rating label will consti- tute forfeiture of all product warranty coverage for any reason. Warranty coverage is applicable only to static equipment installations — the manufacturers products are not intended for installation in transport or mobile applications of any kind. In order to make any claim of warranty coverage you must first contact the equipment ma- nufacturer or their authorized agent and present them with the original unit serial number, date of installation and a full description of the specific failure which has prompted the warranty claim request. Warranty contact information for LU-VE products distributed and sold within the continental US is as follows; Zyklus Heat Transfer - PO Box 60 - Jacksonville, TX 75766 - 903-589-3355 - [email protected] RECEIVING AND INSPECTION When the equipment is initially received, a responsible individual acting on behalf of the equipment purchaser must be present to check the quantity of cartons and crates being delivered against the bill of lading to confirm that all items listed therein are accounted for. In- spect all shipping containers (boxes and crates) for any signs of visible damage. Report any damage or shortages to the delivering freight company immediately. It is the customer's responsibility to file all claims with the freight company. Damaged equipment may be refused but must not be returned to the manufacturer for any reason without prior authorization. Installing personel must excercise caution when removing equipment from crates and boxes to prevent physical injury to themselves or the product. Always wear appropriate personal protection equipment (PPE) such as hard hats, gloves, safety glasses, safety shoes, long sleeve shirts and pants, etc. to avoid physical injury. When lifting smaller units by hand always utilize proper lifting techniques to avoid personal injury. Equipment should be left in the original shipping container whenever possible until just prior to installation. Do not use piping connections, fan guards, drain pans or other such similar components as lifting points. On larger units which must be remo- ved from the shipping container or skid with lifting straps make sure to utilize a spreader bar to avoid damage to the units sheet metal housing. REMOVING EQUIPMENT FROM SHIPPING CONTAINERS / PACKAGING If using a forklift roll the unit over onto a wooden pallet with the shipping skid “up” ( Figure 1 - Steps 1 & 2 - Page 6 ). Remove the banding which holds the cardboard box to the shipping skid, then using a razor knife, carefully cut the box down all (4) cor- ners and fold the cardboard down onto the pallet, leaving the unit resting on the original cardboard shipping blocks and carton top flaps ( Figure 2 - Step 3 - Page 6) . Remove both the left and right side cover panels to gain access to the nuts and bolts holding the front mounting feet to the shipping skid. Remove all (4) bolts and lay aside the shipping skid ( Figure 2 - Steps 4, 5 & 6 - Page 6 ). With the carboard shipping container cut away and the side access panels removed from the unit check closely for any concealed or hidden damage. If any damage is noted, report it to the manufacturer immediately before proceding with the equipment installation. All units are shipped with approx. 25 PSIG of dry air or nitrogen holding charge in the coil. Use an accurate suction service gauge to verify internal coil pressure prior to proceeding with the unit installation. Although the absence of pressure or a lower than normal pressure reading does not necessarily indicate a leak, if the reading is “low” a leak test must be performed before contrinuing with the installation or returning the unit to the distributor or manufacturer (Figure 3 - Step 7 - Page 6) .

RkJQdWJsaXNoZXIy Mzc3NTY=